  technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 1 highligh ts & features ? ultra - compact size and galvanic isolation up to 3.0kvac between input to output and input to ground ? universal ac input voltage and full power from - 10c to +55c operation ? up to 82 .0% efficiency ? low earth leakage current < 0. 7 5ma @ 264vac ? built - in dc ok relay contact option available ? extreme low temperature cold start at - 40c ? nec class 2 / limited power source (lps) certified ( drs - 5v50w1n ? ) safety standards cb certified for worldwide use model number: dr s - 5 v 5 0 w1 ? ? unit weight : 0. 16 kg (0. 35 lb) dimensions (l x w x d): 75 x 30 x 89.5 mm ( 2. 95 x 1. 18 x 3 . 5 2 inch) general description the ultra - compact and compe titively priced delta sync din r ail drs - 5 v 5 0w1 ?? power supply is designed for industrial applications requiring highly reliable power supply that must fit in a small space. the sync series operates with universal ac input range and offers full power up to 55 c. the output is a djustable from 5 - 5 .5 volts , and can support up to 3000 microfarads of load capacitance. a green led indicates output is present. all models in t he series are certified according to iec/en/ul 60950 - 1 information technology equipment (ite) and ul 508 industr ial control equipment (ice). the series is also fully compliant with rohs directive 2011/65/eu for environmental protection. nec class 2 and limited power source (lps) approvals are available for drs - 5v5 0w1n ? . model information sync din rail power supply model number input v oltage range rated output v oltage rated output cur r ent dr s - 5 v 5 0 w1 a ? 85- 264v ac (120 - 375vdc) 5 vdc 6 . 0 a drs - 5 v 5 0w 1n ? 5.0 a model numbering dr s ? 5 v 5 0w 1 din rail product serie s s ? sync series output voltage 5 0w series single phase a ? non nec c lass 2 n ? nec class 2 z ? without dc ok relay contact r ? with dc ok relay contact *this picture is for reference to dr s - 5 v 5 0w series only.
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 2 specifications m odel number drs - 5v5 0w1a ? drs - 5v5 0w1n ? input ratings / charac teristics nominal input v oltage 100- 240v ac input v oltage range 85- 264v ac nominal input f r equency 50- 60hz input f r equency range 47- 63hz dc input voltage range* 120- 375vdc input cur r ent < 0 . 6 a @ 1 15 vac, < 0. 4 a @ 2 30 vac e f ficiency at 100% load > 8 2 % @ 1 15 vac & 230vac max power dissipation 0% load 100% load < 0. 7 w @ 115vac & 230vac < 7.0 w @ 115vac & 230vac max inrush cur r ent (cold start) < 3 0 a @ 115 vac , < 6 0 a @ 230vac leakage cur r ent (neutral to pe terminal) < 0.75 ma @ 2 64 vac *fulfills test condi tions for dc input. safety approval for dc input can be obtained upon request. output ratings / characteristics ** nominal output voltage 5 vdc factory set point tolerance 5 vdc 2% output voltage adjustment range 5 - 5.5 vdc output current 6 . 0 a ( 30 w max .) 5 .0 a ( 25 w max.) output power 30 w 25 w line regulation < 0.5 % (@ 85 - 2 64 vac , 100% load ) load regulation < 1 .0% (@ 85 - 2 64 vac, 0 - 100% load ) pard *** (20mhz) < 5 0 mvpp @ > 0c to 70c < 10 0mvpp @ 0c to - 20c rise time < 3 0ms @ nominal input (100% load) start - up time < 2 , 0 00ms @ 1 15 vac (100% load) < 1, 0 00ms @ 2 30 vac (100 % load) hold - up time > 2 0 ms @ 115 vac , > 100ms @ 230vac (100% load ) dynamic response (overshoot & undershoot o/p voltage) 5% @ 85 - 264vac input, 1 0 - 100% load (slew rate: 0.1a/ s , 50% du ty cycle @ 5hz to 1 k hz) start - up with capacitive loads 3 ,000f max functional dc ok relay contact (for drs - 5 v 5 0w1a r , drs - 5v5 0w1nr ) 30v / 1a , resistive load the relay contact are normally ?on? (closed) when the output (vout) is greater than 75 % of its rat ed value and ?off? (opened) when the output (vout) is less than 75% typ. **for power de - rating from < - 10c to - 20c, and 55c to 70c, see power de - rating on page 3. * **pard is measured with an ac coupling mode, 5cm wires, and in parallel wit h 0.1f ceramic capacitor & 47f electrolytic capacitor.
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 3 m odel number drs - 5v5 0w1a ? drs - 5v5 0w1n ? mechanical case cover / chassis plastic dimensions (l x w x d) 75 x 30 x 89.5 mm (2.95 x 1. 18 x 3.52 inch) unit weight 0. 16 kg (0. 35 lb) indicator g reen led (dc ok) cooling system convection terminal input 3 pins (rated 300v/ 16a ) output 4 pins (rated 300v/16a) wire input / output awg 2 2 - 12 / awg 18 - 12 mounting rail standard ts35 din rail in accordance with en 60715 noise (1 meter from power s upply) sound pressure level (spl) < 25dba environment surrounding air temperature operating - 2 0 c to + 7 0 c (cold start at - 40c @ 40% load ) storage - 40 c to + 85c power de - rating - 1 0c to - 2 0c de - rate power by 2 % / c > 5 5 c de - rate power by 3.33 % / c operating humidity 5 to 95 % rh (non - condensing) operating altitude 0 to 2 ,000 meters (6,560 ft.) shock test non - operating iec60068 - 2 - 27, half sine wa ve: 50g for a duration of 11ms; 3 times per direction, 9 times in total operating iec 60068 - 2 - 27, half sine wave : 1 0 g for a duration of 11 ms; 1 time in x axis vibration non - operating iec 60068 - 2 - 6, random: 5 - 50 0hz ; 2.09 g rm s , 2 0 min per axis for all x, y, z directions operating iec 60068 - 2 - 6, sine wave : 10 - 50 0hz ; 2 g peak ; displacement of 0. 35mm; 1 octave per min; 60 min per axis for all x, y, z direction s pollution degree 2 protections overvoltage < 7 .2 4 5v , selv output, latch mode overload / overcurrent 105~1 2 5 % of rated load current, foldback mode ( continuous current , voltage drops), auto - recovery when the fault is removed over temperature < 75c surrounding air temperature @ 100% load, latch mode short circuit hiccup mode, non - latching (auto - recovery when the fault is removed) internal fuse t3.15a degree of protection ip 20 protection against shock class i with pe * connection *pe: primary earth
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 4 m odel number drs - 5v5 0w1a ? drs - 5v5 0w1n ? reliability data mtbf telcordia sr - 332 > 70 0,000 hrs , i/p: 115vac & 230vac, o/p: 100% load, ta: 25c mil - hdbk - 217f 165 , 3 00 hrs , i/p: 115vac & 230vac, o/p: 100% load, ta: 25c expected cap life time 10 years ( 115ac & 2 30vac , 50% load @ 40c ) safety standards / directives safety entry low voltage selv (en 60950) electrical safety tuv bauart ul/cul recognized cb scheme en 60950 - 1 ul 60950 - 1, csa c22 .2 no. 60950 - 1 (file no. e1 9 1 395 ) i ec 60950 - 1 , limited power source (lps , for drs - 5v5 0wn ? only ) industrial control equipment ul/cul listed ul 508 and csa c22.2 no. 107.1 - 01 (file no. e315335 ) class 2 power supply ul/cul recognized ul 60950 - 1, csa c22.2 no. 60950 - 1(file no. e191395) (for drs - 5v5 0wn ? only) ce in conformance with emc directi ve 20 14/30 /e u and low voltage directive 20 14/ 3 5/e u material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0 kvac input to ground 3 . 0 kvac output to ground 0.5kvac
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 5 m odel number drs - 5v5 0w1a ? drs - 5v5 0w1n ? emc em c / emissions generic standards: en 61000 - 6 - 3, en 61000 - 6 - 4 cispr 22, en 55022 en 55011, fcc title 47: class b component power supply for general use en 61204 - 3 immunity to generic standards: en 55024 , en 61000 - 6 - 1, en 61000 - 6 - 2 electrostatic dischar ge iec 61000 - 4 - 2 level 3 criteria a 1) air discharge: 8kv contact discharge: 6 kv radiated field iec 61000 - 4 - 3 level 3 criteria a 1) 80mhz - 1ghz, 10v/m with 1khz tone / 80% modulation 1.4ghz - 2ghz, 3v/m with 1khz tone / 80% modulation 2ghz - 2.7ghz, 1v/m wit h 1khz tone / 80% modulation electrical fast transient / burst iec 61000 - 4 - 4 level 3 criteria a 1) 2 kv surge iec 61000 - 4 - 5 level 3 criteria a 1) common mode 3 ) : 2 kv differential mode 4 ) : 1 kv conducted iec 61000 - 4 - 6 level 3 criteria a 1) 150khz - 80mhz, 1 0 vrms power frequency magnetic fields iec 61000 - 4 - 8 criteria a 1) 30 a/meter voltage dips and interruptions iec 61000 - 4 - 11 0% of 100vac, 0vac, 20ms 0% of 100vac, 0vac, 500 0ms 4 0% of 100vac, 40vac, 1 0 0ms 70% of 100vac, 70vac, 500ms 0 % of 240vac, 0 vac, 2 0m s 0 % of 240vac, 12vac, 5000ms 40% of 240vac, 96vac, 2 00ms 70% of 240vac , 168vac, 500ms criteria a 1) criteria b 2) criteria b 2) criteria a 1 ) criteria a 1) criteria b 2) criteria a 1) criteria a 1) low energy pulse test (ring wave) iec 61000 - 4 - 12 level 3 criteri a a 1) common mode 3 ) : 2 kv differential mode 4 ) : 1 kv harmonic current emission iec/en 61000 - 3 - 2, class a voltage fluctuation and flicker iec/en 61000 - 3 - 3 1) criteria a: normal performance within the specification limits 2) criteria b: temporary degrada tion or loss of function which is self - recoverable 3) asymmetrical: common mode (line to earth) 4) symmetrical: differential mode (line to line)
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 6 block diagram drs - 5 v 5 0w1 ?z drs - 5v5 0w1 ?r
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 7 device description drs - 5 v 5 0w1az drs - 5 v 5 0w1nz 1) inp ut terminal block connector 2) output terminal block connector 3) dc voltage adjustment potentiometer 4) dc ok led (green) 5) universal mounting system drs - 5 v 5 0w1ar drs - 5 v 5 0w1nr 1) input terminal block connector 2) output terminal block connector 3) dc ok relay conta ct 4) dc voltage adjustment potentiometer 5) dc ok led (green) 6) universal mounting system
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 8 dimensions l x w x d: 75 x 30 x 89.5 mm [2.95 x 1.18 x 3. 52 inch] drs - 5 v 5 0w1a z l x w x d: 75 x 30 x 89.5 mm [2.95 x 1.18 x 3.52 inch] drs - 5 v 5 0w1a r
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 9 l x w x d: 7 5 x 30 x 89.5 mm [2.95 x 1. 18 x 3 . 5 2 inch] drs - 5 v 5 0w1nz l x w x d: 75 x 30 x 89.5 mm [2.95 x 1.18 x 3.52 inch] drs - 5 v 50 w1n r
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 10 engineering data output load de - rating vs surrounding air temperature output load de - rating vs input voltage note 1. power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2. if the output capacity is not reduced when the surrounding air temperature >55 c, the device will run into over temperature protection. when activated, power supply will latch off, until the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition, and require removal/re - application of input ac voltage in order to restart. 3. in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 80mm (3.14 inch) above and below the device as well as a lateral distance of 25mm (0.98 inch) to other units while the device is in operation. 4. depending on the surroundi ng air temperature and output load delivered by the power supply, the device can be very hot! 5. if the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. fig. 1 de - r ating for vertical mounting orientation - 10c to - 20c de - rate power by 2 % / c > 55c de - rate power by 3.33% / c ? no output power de - rating across the entire input voltage range
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 11 assembly & installation the power supply unit (psu) can be mounted on 35mm din rails in accordance with en60715. the device should be installed with input terminal block at the bottom. each device is delivered ready to install. mounting safety instructions dismounting fig. 2.1 mounting snap on the din rail as shown in fig. 2.1: 1. tilt the unit slightly upwards and put it onto the din rail. 2. push downwards until stopped. 3. press against the bottom front side for locking. 4. shake the unit slightly t o ensure that it is secured. ? always switch mains of input power off before connecting and disconnecting the input voltage to the device . if mains are not turned off, there is risk of explosion / severe damage. ? to guarantee sufficient convection cooling, keep a distance of 8 0mm (3.14 inch) above and below the device as well as a lateral distance of 25 mm (0.98 inch) to other units. ? note that the enclosure of the device can become very hot depending on the surrounding air temperature and output load connecte d to the device. risk of burns! ? the main power must be turned off before connecting or disconnecting the wires to the terminals! ? do not insert any objects into the device. ? dangerous voltages present for at least 5 minutes after disconnecting all sources o f power. ? the power supplies unit should be installed in minimum ip54 rated enclosure. ? the power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. fig. 2.2 dismounting to uninstall, pull or slide down the latch with screw driver as shown in fig. 2.2. then slide the power supply unit (psu) in the opposite direction, release the latch and pull out the power supply unit (psu) from the rail.
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 12 functions graph illustrating the start - up time, rise time, and hold - up time start - up time the time required for the output voltage to reach 90% of its final steady state set value, after the input voltag e is applied. rise time the time required for the output voltage to change from 10% to 90% of its final steady state set value. hold - up time time between the collapse of the ac input voltage, and the output falling to 95% of its steady state set value. inrush current inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response the power supply output voltage will remains within 5% of its steady state value, when subjected to a dynamic load from 10% to 100% of its ra ted current. ? 50% duty cycle / 5hz to 1 k hz
technical d at asheet sync din rail power supply 5v 50w series / drs - 5v50w1a / drs - 5v50w1n all parameters are specified at 25 c ambient and ac input unless otherwise indicated. www. deltapsu .com (june 2016 , rev. 00 ) 13 overload & overcurrent protections (auto - recovery) the power supply?s over load (olp) and over current (ocp) protection s will be act ivated when output current is about 6.0a typ. for drs - 5v50w1n ? and 6.7a typ. for drs - 5v50w1 a ? . w hen this occurs, the v o will start to droop (refer to ? below). once the output voltage is below about 1.4 vdc typ ., the power supply will start to operate in ?hiccup mode? (auto - recovery mode). the power supply will recov er once the fault condition of the ocp is removed and output current is back within the specifications. short circuit protection (auto - recovery) the power supply?s output short circuit protection function also provides protection against short circuit s. when a short circuit is applied, the output current will operate in ?hiccup mode?. the power supply will return to normal operation after the short circuit is removed. overvoltage protection (latch mode) the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. power supply will latch off, and require removal/re - application of input ac voltage in order to restart. the power supply should be latch. over temperature protection (latch mode) as described in load de - rating section, the power supply also has over temperature protection (otp). in the event of a higher operating temperature at 100% load; or, when the operating temperature is beyond what is recommended in the de - rating graph, the otp circuit will be activated. when activated, power supply will latch off, until the surrounding air temperature drops to its normal operating temperature or the load is reduc ed as recommended in the de - rating graph. removal/re - application of input ac voltage will then be required in order to restart. delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous subst ances in electrical and electronic equipment?. this product conforms to this standard.


▲Up To Search▲   

 
Price & Availability of DRS-5V50W1AX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X